adtran total access 612 manual

adtran total access 612 manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF


File Name:adtran total access 612 manual.pdf
Size: 1479 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 9 May 2019, 22:29 PM
Rating: 4.6/5 from 646 votes.

Status: AVAILABLE


Last checked: 9 Minutes ago!

In order to read or download adtran total access 612 manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version



✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers


adtran total access 612 manual

Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. ADTRAN reserves the right to change the contents without prior notice. The purpose of this manual is to provide the technician, system administrator, and manager with general and specific information related to the planning, installation, operation, and maintenance of the Total Access 6XX. This manual is arranged so that needed information can be quickly and easily found. There is a remote risk of shock from lightning. Do not dispose of batteries in a fire. They may explode. Check with local codes for special disposal instructions. If requested, provide this information to the telephone company. If possible, advance notification is given; otherwise, notification is given as soon as possible. The telephone company will advise the customer of the right to file a complaint with the FCC. Advance notification and the opportunity to maintain uninterrupted service are given. The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning. This equipment is designed for connection to the telephone network or premises wiring using an FCC compatible modular jack, which is compliant with Part 68 and requirements adopted by ACTA. In most areas, the sum of the RENs of all devices should not exceed five. To be certain of the number of devices you may connect to your line as determined by the REN, call your telephone company to determine the maximum REN for your calling area. Connection to party lines is subject to state tariffs. Contact your state public utility commission or corporation commission for information. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

http://gaiabits.com/userfiles/diesel-engine-overhaul-manual.xml

    Tags:
  • adtran total access 612 manual, adtran total access 612 manual, adtran total access 612 manual pdf, adtran total access 612 manual user, adtran total access 612 manual download, adtran total access 612 manual transmission.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. With respect to encoded This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department of Commerce does not guarantee the equipment will operate to the user's satisfaction. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. This precaution may be particularly important in rural areas. The termination on a loop may consist of any combination of devices subject only to the equipment that the total of the LNs of all devices does not exceed 100. The sum of the RENs from all devices in the circuit should not exceed a total of 5.0. Please take time to register your products on line at www.adtran.com. Click Service and Support on the top of the page, and then click Product Registration under Support. For service, RMA requests, training, or more information, use the contact information given below. CAPS should also be contacted to obtain information regarding equipment currently in house or possible fees associated with repair.

http://www.tortugafilms.com/adminfiles/diesel-engine-manuals-online.xml

If additional pre-sales support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, latest product documentation, application briefs, case studies, and a link to submit a question to an Applications Engineer. All of this, and more, is available at: If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble-shooting tools. All of this, and more, is available at: Please have your unit serial number available when you call. This support is available at: These courses include overviews on product features and functions while covering applications of ADTRAN's product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at your site. For more information about training, please contact your Territory Manager or the Enterprise Training Coordinator. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions. Each section details the Management Information Bases (MIBs) supported, MIB Compilation Order, Traps Supported, and MIB Variables supported. The Total Access 600 Series benefits integrated communications providers (such as CLECs, ILECs, and ISPs) who require a customer premises device with integrated voice and data functions, and provides a viable migration path from TDM to packet-based technology. These IADs support applications such as VoDSL and VoATM. An optional battery backup is also available for many of the models. The last two digits of the product name indicate the number of on-board FXS ports. The Total Access 604 contains four FXS ports, the Total Access 608 contains eight FXS ports, etc. The units can provision, test, and provide status for any of the voice and data interfaces.

http://fscl.ru/content/boss-me-50-manual

All connections are made via the rear panel. The development of A.04.XX code is a significant step in the evolution of the Total Access product line, as it allows all Total Access family members to share the same base code. This means that features and fixes are more easily implemented and are propagated across the product line. The User Interface Guide section of this manual represents the A.04 firmware changes. There are two possible upgrade paths: (1) Upgrading from A.03 to A.04 directly and; (2) Upgrading from A.03 to A.03.92 (Transition Build) to A.04. Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit’s configuration. See DLP-14, A.03 to A.04 Firmware Upgrade, for more details. Refer to the following information if an older version of software is to be loaded into the unit. For TDM applications, please use software revision A.03.58 or later. For ATM applications, software revision D.01.30 or later is required. Using incompatible software will cause the unit to malfunction. For more information or technical assistance, please call ADTRAN Technical Support at 888-4ADTRAN. Please have the unit serial number available when contacting Technical Support. Some features are model-dependent. The following list displays the various available systems grouped by network technology. Table 3 provides LED descriptions for Total Access 600R systems. The LED functionality varies based on product and software load (TDM versus ATM).The LED functionality varies based on product and software load (TDM versus ATM).The Total Access 600R rear panel differs from the rest of the family in that it does not have a VOICE connection (50-pin amphenol connector). Figure 4 illustrates a standard Total Access 600R rear panel. In addition, systems can include either a LIFE LINE analog interface (via an RJ-48 connector) or an optional DSX-1 interface (via an RJ-48 connector).Figure 11 shows the VOICE connector pinout.

http://oficinasdeteatro.com/images/colt-government-380-manual.pdf

This adapter is not part of the Total Access 600 Series shipment. You can also build your own adapter by purchasing unassembled adapter kits from Black Box or Datacomm Warehouse (or other equivalent companies). The adapter pinout is shown in Table 8. For more details on the battery backup system installation and operation, refer to the documentation available for your specific battery backup unit. Connect the power supply to a standard 120 VAC, 60 Hz electrical outlet for proper operation. The first port of the voice connector is provided with analog voice from the LIFE LINE analog connection. A regular POTS line must be plugged into the LIFE LINE port. Table 11 provides the LIFE LINE port pinout. Total Access 600 Series systems without the DSX-1 interface are not field-upgradeable to add DSX-1 access. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded. Open each carton carefully and avoid deep penetration into the carton with sharp objects. If the equipment has been damaged in transit, immediately file a claim with the carrier, and then contact ADTRAN Customer Service (see Bare, covered, or insulated grounding conductors are acceptable. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes. The equipment grounding conductor is to be connected to ground at the service equipment. The supplementary equipment grounding conductor shall be connected to the product at the terminal provided, and shall be connected to ground in a manner that will retain the ground connection when the product is unplugged from the receptacle.

Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground. Wallmount brackets are included with the unit and are already attached.Keep in mind that the unit needs to be mounted at or below Using sheetrock anchors may not provide As shipped, the unit is set to factory default conditions. After installing the unit it is ready for power-up. To apply power to the unit, ensure that it is properly connected to an appropriate power source. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions. Configure the terminal settings for 9600 data rate, no parity, 8 data bits, 1 stop bit, and no flow control. The left pane shows the list of available submenus, while the right pane shows the contents of the currently selected submenu. Viewing submenus vertically rather than horizontally allows you to see information at a glance rather than scrolling horizontally across the window. Figure 2 on page 44 shows this alternate view. Fields and submenu names may vary slightly in this view. These contents include both submenu items and data fields. Some submenus contain additional submenus and some data fields contain additional data fields. The following chart explains the notation used to identify these additional items. No entry will appear for slots not containing a module. This information is not displayed when connecting to the system via the CRAFT interface. Save changes by backing out to the main menu, or press to force a manual save. Press to activate a pop-up screen listing the navigation keystrokes. When the cursor is positioned over a set of configuration items, a help message displays (when available) providing a description of the item. At this point, pressing displays a pop-up help screen with information about the item.

Press to remove these help screens. Each menu item has several functions and submenus that identify and provide access to specific operations and parameters. Use the following chart to help select the appropriate menu. Connecting to the system through the rear CRAFT interface automatically provides maximum rights. Table 1 describes the security levels. T1 ATM Total Access 604. T1 ATM Total Access 612. T1 ATM Total Access 616. T1 ATM Total Access 624. April 2002. Total Access 600 Series User Manual. Page 2. Trademarks. Any brand names and product names included in this manual are trademarks,To the Holder of the Manual. The contents of this manual are current as of the date of publication. ADTRANIn no event will ADTRAN be liable for any special, incidental, or consequentialP.O. Box 140000. Huntsville, AL 35814-4000Printed in U.S.A. Page 3. Notes provide additional useful information. Caution signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment orSafety Instructions. When using your telephone equipment, please follow these basic safetyThere is a remote risk of shock from lightning.Do not dispose of batteries in a fire. They may explode. Check with localSave These Important Safety Instructions. Page 4. FCC regulations require that the following information be provided in this manualOn the side of the bottom of this equipment is a label that contains, among other information, the. FCC Registration Number and Ringer Equivalence Number (REN), if applicable, for this equipment. If required, this information must be given to the telephone company.See installation instructions for details.If possible,But if advance notice isn’t practical, you willYou will be advised of your right to file a complaint with the FCC.

The telephone company may ask you toExcessive RENs on the telephone line may result in theIn most, but not all areas,Federal Communications Commission Radio Frequency Interference Statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuantThese limits are designed to provide reasonable protection against harmfulThis equipment generates,Operation of this equipment in aShielded cables must be used with this unit to ensure compliance with Class A FCC limits. Changes or modifications to this unit not expressly approved by the party responsibleTotal Access 600 Series User Manual. Page 6. Industry Canada Compliance Information. Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or theNotice: The Ringer Equivalence Number (REN) for this terminal equipment is supplied in the. The REN assigned to each terminal device indicatesThe termination on anRENs of all the devices should not exceed five (5). Canadian Emissions Requirements. This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatusDepartment of Communications.Total Access 600 Series User Manual. Page 7. Warranty and Customer Service. ADTRAN will repair and return this product within ten years from the date of shipment if it does not meetFor detailed warranty, repair, and return informationReturn Material Authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, or further information, contact one of the numbers listed at the end of thisADTRAN will be free from defects in materials and workmanship.

ADTRAN also warrants that productsManual or in ADTRAN's internal specifications and drawings for such products (which may or may not beThis warranty only applies if Customer gives ADTRAN written notice ofUpon such notice, ADTRAN will, at its option, either repair or replaceThis warranty becomes null and void if CustomerADTRAN is not liable for damagesTotal Access 600 Series User Manual. Page 8. Customer Service, Product Support Information, and Training. ADTRAN will repair and return this product if within ten years from the date of shipment the product doesA return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service. RMA requests, training, or more information, use the contact information given below. Repair and Return. If you determine that a repair is needed, please contact our Customer and Product Service (CAPS)CAPS should also be contacted to obtain informationCAPS DepartmentADTRAN Customer and Product ServiceHuntsville, Alabama 35806. Pre-Sales Inquiries and Applications Support. Your reseller should serve as the first point of contact for support. If additional pre-sales support is needed,Applications Engineer. All of this, and more, is available at:Department. Applications Engineering (800) 615-1176. Page 9. Post-Sale Support. If additional support is needed, the. ADTRAN Support web site provides a variety of support services such as a searchable knowledge base,All of this, and more, is available at:Technical SupportThe ADTRAN Custom Extended Services (ACES) program offers multiple types and levels of installationThis support isACES Help DeskThe Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and functions while covering applications of. ADTRAN's product lines. ADTRAN provides a variety of training options, including customized trainingFor more information about training, please contact your.

Territory Manager or the Enterprise Training Coordinator. Training PhoneTraining FaxTotal Access 600 Series User Manual. Page 10It contains overview information, configuration details for Voice Over ATM, menu descriptions, andTotal Access 600 Series User Manual. Page 12. Page 13. Page 14. Provides a user-configurable text string for the name of the TA 600. This name can help you distinguish between different installations. You can enter up to 31 characters in this field, including spaces and special characters (such as anProvides a user-configurable text string for the location of the TA 600. This field is to help you keep track of the actualYou can enter up to 31 characters in this field, including spaces and special charactersProvides a user-configurable text string for a contact name. You can use this field to enter the name, phone number,You can enter up to 31 characters in this field, including spaces and special characters (such as an underbar). Product-specific name for the product assembly. CLEI code for the product assembly. Page 20. ADTRAN part number for the product assembly. Serial number of the product assembly. Displays the current firmware revision level of the controller. Displays the bootcode revision. Displays the length of time since the TA 600 system reboot. Displays the current date and time, including seconds. This field can be edited. Enter the time in 24-hour format (suchEnter the date in mm-dd-yyyy format (for example, 10-30-1998). Each time you reset the system, this value resets to 0 days, 0 hours, 0 min and 0 secs. Page 21. System Config. Set up the Total Access 600 operational configuration from the 6 Network Timing Mode. Selects the timing source for the entire system. Network is the only timing option available. Network. The system’s clock is recovered from the network (WAN interface). Sets Telnet access to 21 or 2)). Up to four users can be configured for access to the Total Access 600.

Each user can be assigned a security level andName. A text string of the user name for this session. Authen Method. The user can be authenticated in two ways:Password. Idle Time (1-255). This sets the amount of time you can be idle before you are automatically logged off. Page 22. Level. This is the security level granted to the user. The setup forPassword Protect. When set to 12, the maintenance port is not password protected. When Network Time. The Total Access 600 unit time can be entered manually from the6 Upgrade Firmware. Updates firmware when TA 600 enhancements are released. Two transfer methods are available for use in updatingTransfer Method. The two methods for upgrading are;02'(0and7)73 (See Appendix A. Updating Total Access 600. Firmware using XMODEM on page 55 and Appendix B. Updating Total Access 600 Firmware using TFTPTotal Access 600 starts a TFTP client function which gets the upgrade code from the TFTP server. Selecting. TFTP Server Address. This is required when the transfer method is TFTP. It is the IP address or domain name (if DNS is configured) of the TFTP server. TFTP Server Filename. It is the case-sensitive file name which contains theTransfer Status. This appears when TFTP is used. It displays the status of the transfer as it happens. Any error or successTotal Access 600 Series User Manual. Page 25. Start Transfer. This activator is used when the configurable items in this menu are complete.Abort Transfer. Use this activator to cancel any TFTP transfer in progress. Used only with TFTP transfers. Sends a file containing the TA 600 configuration to a file on a TFTP server using theTo support these transfers, ADTRAN delivers a TFTP program with the TA 600 called TFTP Server. You can configure any PC running Microsoft Windows with this software, and store a configuration file. See Appendix B. Updating. Total Access 600 Firmware using TFTP on page 58 for details on how to use TFTP Server.

Only one configuration transfer session (upload or download) can be active at a time. Transfer Method. Displays the method used to transfer the configuration file to or from a server. Currently, you must useAllows you to send pings (ICMP requests) to hosts. The following items are under this menu. Only one ping session can be active at a time. Activator to start and cancel a ping test. Host Address. IP address or domain name (if DNS is configured) of device to receive the ping. Size (40-1500). Total size of the ping to send. Range is 40 (64 is def) to 1500 bytes. Total packets to send every 2 seconds. Setting this to allows the client to ping continuously. Total packets sent (read only). Total packets received (read only).Percentage loss based on ping returned from host (read only). Page 27. Configuring WAN Settings. Set this to the type of DSLAM the Total Access 600 will be connecting to. This is the physical layer protocol used to connect the DSLAM to the Total Access 600. This is the data link layer protocol used to connect the DSLAM to the Total Access 600. If the DSLAM Type is CopperMountain, refer to Appendix H. Routing in HDIA Mode on page 71 forFigure 6. WAN Menu. Page 28. Figure 7. ATM Config Menu. Idle Cells. Configuring this setting incorrectly for a particular circuit will cause poor performance at the ATM layer. This setting must match the configuration setting of the ATM switch or DSLAM at the other end ofData Scrambling. Configuring this setting incorrectly for aThis setting must match the configuration setting of the ATM switch or DSLAM at the other end ofTotal Access 600 Series User Manual. Page 29. Figure 8. ATM Stats Menu. AP: Tx Cells. This is the number of cells transmitted. AP: Rx Cells. This is the number of cells received. AP: Rx OAM Cells. This is the number of OAM cells received. AP: Receive Cells Discarded. This is the number of cells received and discarded.

An incrementing count in this field could indicate a configuration problem with the ATM layer. AP: Receive Cell Errors. This is the number of cells received with an HEC error. AP: Sync. This indicates cell delineation at the ATM layer. AP: Out Of Cell Delineation. This indicates loss of cell delineation at the ATM layer. AAL5: Transmit Frames. This is the number of AAL5 frames transmitted. AAL5: Receive Frames. This is the number of AAL5 frames received. AAL5: Transmit Discarded Frames. This is the number of AAL5 frames discarded. Page 30. AAL5: Receive Errors. This is the number of AAL5 errors received. AAL5: Receive Discarded Frames. AAL5: No ATM Frames. This is for internal use only. AAL5: No Data Packets. This is for internal use only.Clear Stats. This is used to clear the counters on this menu screen. Page 31. Figure 10. Global MenuMode. This item controls how the 600 handles IP routes. When this option is set to 21(def), the 600 willIf 2)), the route table is still used, but only staticIP packets can be sent over the. WAN, but only when bridged. Page 32. Static Routes. Use this menu to enter static routes to other networks.Figure 11. Ethernet MenuIP Address. The IP address assigned to the 600's Ethernet port is set here. This address must be unique within theSubnet Mask. This is the IP network mask that is to be applied to the 600's Ethernet port. Default Gateway. The default gateway is used by the 600 to send IP packets whose destination address is not found in theTotal Access 600 Series User Manual. Page 37Choices are V1 (def)Proxy ARP. This feature allows the network portion of a group of addresses to be shared among several physicalProxy ARP makes use of this mapping feature by instructing aThis technique effectively hides the fact thatIf this option is set to WAN. Figure 12. WAN Menu. L2 Protocol. Displays the current L2 protocol - ATM (Read Only).Description. This is the text description for the PVC.Protocol. This is the protocol supported on the PVC.

Active. This selection enables IP on this PVC. Page 39. Far - End IP Address. This is the address of the NEXT hop router on this interface. IP netmask. This is the network mask used for this interface. Local IP Address. This is the IP address for this PVC.During transmission, private addresses are translated into a singleIncoming packets areOnce enabled, you mustThe port translation requires at least a single real IPThis value can use the IP assigned to the interface (or assigned via layer 2 protocol like PPP), obtained using DHCP client, orIf the address cannotThe public IP address used for this translationYou specify an address toThe upper layer protocol that is to be monitoredThe public destination port associated with thisThis menu maintains statistics about the active ATM PVCs. This is a listing of the currently connected Ethernet port on the LAN. This shows the detected MAC addresses and the interface to which they are associated. Page 45. This shows the current routes in the 600 and their use. This shows traffic over the LAN interface. This shows IP traffic through the 600. The Logs menu (Figure 14) contains logs displaying important information about the running condition of the Total. Access 600. The logs can be set to capture diagnostics of error conditions only by way of a log level. The levels areSys log Host. Set this to the IP address or domain name (if DNS configured) of the sys log host device. All log events are sent to thisPPP Log. Information pertaining to the PPP negotiation and authentication is logged in the PPP log. Page 46. Connection Log. Information pertaining to the call placement and answering is logged in the Connection log. Network Log. Information pertaining to routing protocols is placed in this log. Each log (PPP log, Connection log, and Network log) contains the following elements. Active. When set to Call ControlThe Total Access 600 supports Jetstream, Tollbridge, and CopperCom. Voice Gateways.

The 93, setting is used to configure the Total Access 600 virtual path setting used to communicate with the configured. Voice Gateway. Page 48. Access 600 IAD for voice signaling and voice payload delivery. From this menu. Several statistics at this menu are used onlyTask, Inserts, and Drops indicators are for internal use only. Page 49. The Total Access 600 contains four fixed. Figure 17. Modules Menu. Menu. Format. Sets the frame format for the T1 interface. The setting must match the frame format of the circuit toLine Code. Sets the line code for the T1 interface. The setting must match the line code of the circuit to which theEqualization. Sets the line build-out for the T1 interface. The setting of this field depends on whether the circuit isChoices are 0dB,-7.5dB,-15dB,22dB,266FT,399FT,533FT,and 655 FT. Page 50. CSU Lpbk. Enables or disables far-end commanded loopbacks via the FDL channel. Test. These options are used to initiate local and remote loopback tests and display the test status. Loc LBNone. Line. Metallic loopback.

Designed & Built by ZuPP

 

Designed & Built by ZuPP

 

 

CONTACT

 

 

B.O. Sport

Bospoort 14, B- 3680 Maaseik

+32 89 56 32 24

 

info@bosport.be