foxboro multivariable transmitter manual

foxboro multivariable transmitter manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF


File Name:foxboro multivariable transmitter manual.pdf
Size: 3742 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 18 May 2019, 15:32 PM
Rating: 4.6/5 from 696 votes.

Status: AVAILABLE


Last checked: 2 Minutes ago!

In order to read or download foxboro multivariable transmitter manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version



✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers


foxboro multivariable transmitter manual

We’re here to help! For more details, please read our We are excited that you have joined the group. You will receive your first welcome message soon. It will describe the email program and what to expect in the upcoming weeks. Enjoy. It transmits a 4 to 20 mA or digital output signal, as applicable, using HART digital communication for remote configuration, calibration, and monitoring. When used with a primary flow element, it also calculates process density and flow rate, and provides transmission of all the measured and calculated values. Using measured process pressure and temperature, the IMV30continuously calculates process fluid density. When used with any of a variety of differential pressure-producing primary flow devices, the transmitter calculates mass or standard volume flow rate. The transmitter provides full dynamic compensation for all variables affecting the flow rate calculation. FEATURES One transmitter for many applications: Individual measurements on a 2-wire loop. Multiple measurements digitally. Assigns 4 to 20 mA to any measurement. Complete configuration using a Model PCMV PC based configurator; limited configuration with optional LCD indicator, or HART communicator. Calculates mass, volume, or standard volume flow rate based on multiple measurements, using a primary flow element. Standard 5-year warranty. Convenient module change allows easy migration between communication protocols. Designed for hazardous area installations; versions available to meet agency flameproof and zone requirements. CE marked; complies with EMC, ATEX, and PED European Directives; and NAMUR NE 21 interference immunity requirement, and NAMUR 105 overrange and underrange annunciations. One transmitter replaces three separate transmitters, saving initial purchase costs.

http://www.helpenergy.cz/userfiles/fppc-campaign-disclosure-manual.xml

    Tags:
  • foxboro multivariable transmitter manual, foxboro multivariable transmitter manual, foxboro multivariable transmitter manual instructions, foxboro multivariable transmitter manual diagram, foxboro multivariable transmitter manual pdf, foxboro multivariable transmitter manual user.

Key Benefits Simple, elegant sensor packaging uses very few parts to achieve exceptionally high reliability Liquid Crystal Display (LCD) digital indicator with on-board pushbutton configuration and calibration. Best in the industry - 5 year warranty Reduced process penetrations save money and reduce chances of fugitive emissions. Fewer transmitters, less wiring, and fewer shutoff valves reduce installation costs. Greater reliability due to fewer devices and less wiring means less chance of losses from downtime or process upsets. Flow rate values from the transmitter eliminate allocation of system resources for flow rate calculations, reducing system costs. High functionality and high performance provide exceptional value. Numerous options and accessories offered to expand the capabilities of these transmitters. They all use field-proven silicon strain gauge sensors and common topworks. DIGITAL HART AND 4 TO 20 mA DC (VERSION -T ELECTRONICS) 4 to 20 mA with HART communications allows direct analog connection to common receivers while still providing full digital communications using a HART Communicator, PC-based configurator, or optional LCD indicator. For complete configuration capability, Foxboro Model PCMV PC-based configurator is required. A HART Communicator PC-based configurator, or optional LCD indicator can be used for routine transmitter functions such as rezeroing or changing damping settings. See Figure 15 for more information on Option L1, LCD indicator. OPTIONAL CUSTOM FACTORY CONFIGURATION (OPTION -C2) Changes can be made to the IMV30 using a HART Communicator, PC-based configurator, or the optional local display. These configuration methods cannot configure the IMV30 for a specific application, but can only modify some parameter values after the initial configuration. Therefore Invensys recommends that IMV30 transmitters be factory configured at time of shipment if the application information is known.

http://ruxthai.com/userfiles/fppc-campaign-disclosure-manual-1.xml

In order to supply the necessary information to the factory, an Option -C2 Configuration Wizard must be run and the results must be available to BuyAutomation. If the Factory Configuration Option (Option -C2) is not selected in the Model Code, the user must then have Model PCMV configuration software to fully configure the IMV30 transmitter for flow rate applications. The Device Descriptions and Device Type Manager files available from Invensys can modify some configuration parameters, but only the Model PCMV will calculate the necessary coefficients related to the process liquid and pass them to the transmitter. Easy-to-use configurator provides selections for for all user applications. ANALOG OR DIGITAL TRANSMISSION The 4 to 20 mA analog output can be assigned to any one of the following variable: Differential Pressure Absolute Pressure Process Temperature Sensor Temperature Electronics Temperature Flow Rate Density (at actual pressure and temperature,and based on known fluid parameters) Also, these variables can be read digitally usng the Model PCMV PC-based configurator or HART Communicator. All of the variables may be read digitally using the Model PCMV PC-based Configurator or HART Communicator. OPTIONAL LCD DIGITAL INDICATOR A digital indicator (see Figure 15) with on-board pushbuttons is available to display the measurement with a choice of units. Pushbuttons allow zero and span adjustments, as well as routine local configuration changes. UNIQUE PROCESS COVER AND CELL BODY DESIGN Biplanar Construction maintains the traditional horizontal process connections and vertical mounting by providing a cell body contained between two process covers, while still achieving light weight, small size, and high static pressure rating. This provides easy retrofit of any conventional differential pressure transmitter, and also is easily mounted in the horizontal position with vertical process connections, when required.

https://labroclub.ru/blog/eiv-system-user-administration-manual-0

Process Covers are fully supported by the cell body over their entire height. This prevents bending and results in a highly reliable seal. Also, this provides dimensional stability to the process covers, ensuring that they will always mate properly with 3- valve bypass manifolds. Process Cover Bolts are enclosed to minimize corrosion and to minimize early elongation with rapid temperature increases. The design makes it less likely for the transmitter to release process liquid during a fire. Process Cover Gaskets are ptfe as standard; ptfe provides nearly universal corrosion resistance, and eliminates the need to select and stock various elastomers to assure process compatibility. ATEX Flameproof Design allows transmitter to be installed in hazardous locations requiring ATEX Flameproof rating. Light Weight provides ease of handling, installation and direct mounting without requiring costly pipe stands TRADITIONAL STRUCTURE The traditional structure utilizes the right angle design common to most differential pressure transmitters in use throughout the world. Process connections are oriented 90 degrees from the transmitter centerline. This traditional structure makes it easy to retrofit any transmitters of similar design. Sensor cavity venting and draining is provided for both vertical and horizontal transmitter installation,using innovative tangential connections to the sensor cavity. Optional side vents are offered for sensor cavity venting in the upright position An extensive variety of process-wetted materials are available for the process covers on this highly versatilea and widely used transmitter. Output Signal and Configuration 4 to 20 mA with HART Communications. When configured for multidrop applications, the mA signal is fixed at 4 mA to provide power to the device.Configurable with a HART Communicator, ModelPCMV Configurator, or optional LCD indicator. Model PCMV required for flow rate applications.

Suppressed Zero and Elevated Zero Suppressed or elevated zero ranges are acceptable provided Span and Range Limits are not exceeded. Zeroing for Nonzero-Based Ranges Dual Function Zeroing from the LCD indicator pushbuttons allows differential pressure zeroing with either zero differential or LRV differential applied. This greatly simplifies position effect zeroing on many pressure and level applications. The PC-based configurator or HART Communicator provides zeroing at any user-entered value. Write Protect Jumper Can be positioned to lock out all configurators from making transmitter database changes. This makes transmitter suitable for safety shutdown system applications that require this feature. Field Wiring Reversal No transmitter damage. Minimum Allowable Absolute Pressure vs.Transmitter Temperature. FUNCTIONAL SPECIFICATIONS Configuration and Calibration Data, and Electronics Upgradeability All factory characterization data, and user configuration and calibration data, are stored in the sensor. This means that the electronics module can be replaced or changed from one type to another. A module may be replaced without the need for reconfiguration or recalibration. Although module replacement can affect accuracy up to 0.20 of span, this error can be removed by an mA trim without application of pressure. Option -C2: Optional Custom Configuration For the transmitter to be custom configured by the factory, the user must complete the Multivariable Configuration Wizard before entering the order, this being the recommended procedure. If Option -C2 is not selected, a standard default configuration will be provided. The user will then need to completely configure the transmitter using the Model PCMV. Option -L1: Optional Liquid Crystal Display (LCD) Digital Indicator with On-Board Pushbuttons Indicator provides: Two Lines; five numeric characters on top line (four when a minus sign is needed) and seven alphanumeric characters on bottom line.

Measurement Readout; value displayed on top line, and units label displayed on bottom line. Configuration and Calibration Prompts. Stability (Long Term Drift) Calibration Frequency The calibration frequency is five years. Any zero effect caused by mounting position can be eliminated by rezeroing. There is no span effect. Options include NACE Class B7M bolting, 17-4 ss bolting, and 316 ss bolting. For the NACE B7M bolting option. Electronics Module Printed wiring assemblies are conformally coated for moisture and dust protection. Electronics Housing and Housing Covers Housing has two compartments to separate the electronics from the field connections. The housing and covers are made from low copper, die-cast aluminum alloy with an epoxy finish, or from 316 ss. Buna-N O-ring seals are used to seal the threaded housing covers, housing neck, and terminal block. Electrical Connections. Wires terminate under screw terminals and washers on terminal block in the field terminal compartment. Mounting Position The transmitter may be mounted in any orientation. All rights reserved. Schneider Electric’s Innovation Summits are all about preparing you to lead in this era.Please try again later.For more details, please read our We are excited that you have joined the group. It is an ideal solution when a number of individual measurements are to be brought into a system for monitoring, control, or calculation. The IMV25 is available with a choice of HART, Modbus, Foundation Fieldbus, or FoxCom digital communications. A single 4 to 20 mA analog output is also provided. NEMA 4X and IEC IP66 durable epoxy-coated aluminum, or 316 ss housings. Can be provided with numerous configurations of direct connect or remote mount seals. FEATURES One transmitter for many applicationsIndividual measurements on a 2-wire loop Multiple measurements digitally Assigns 4 to 20 mA to any measurement. Select a transmitter with traditional or low profile structures. HART for remote communication.

Convenient module change allows migration between protocols. Remote configuration using a host or Model PCMV PC-based configurator. Local configuration available with the optional LCD indicator with on-board pushbuttons. Reduced process penetrations save money and reduce chances of fugitive emissions. One transmitter replaces three separate transmitters - means less wiring, fewer shutoff valves, and reduced installation costs. Durable aluminum or 316 ss housing available; both meet NEMA 4X and IEC IP66. Complies with NAMUR NE 21 Interference Immunity requirement, and NAMUR 105 overrange and underrange annunciations. CE marked; complies with EMC, ATEX, and PED European Directives. Optional standard and universal style mounting bracket sets allow installation flexibility. Numerous other options and accessories expand the capabilities of these transmitters. Refer to TI 37-75b for process applicability with these wetted parts. EASE OF INSTALLATION Rotatable Topworks Allows installation in tight places Positions indicator in preferred direction Eases field retrofit Two Conduit Connections Provide for easy wiring Allow self-draining of condensation Wiring Guides and Terminations Provide easy wire entry and plenty of space Use large, rugged screw terminals for easy wire termination. FLAMEPROOF AND EXPLOSIONPROOF DESIGN Transmitter meets numerous agency requirements for hazardous area locations. Versions available to meet agency flameproof and zone requirements. DIGITAL AND 4 TO 20 mA OUTPUT The IMV25 provides 4 to 20 mA and digital output using the HART communication protocol. Digital HART and 4 to 20 mA dc (Version -T Electronics) 4 to 20 mA with HART communications allows direct analog connection to common receivers while still providing full Intelligent Transmitter Digital Communications using a HART Communicator or Model PCMV Configurator. Users having HART Communicators for other devices can have them upgraded with Invensys software to accommodate these transmitters.

When configured for digital output, any three of the five variables listed above can be selected for remote communication with HART Communicator or Model PCMV PC-based Configurator. MODEL PCMV CONFIGURATOR This Windows-based software package displays measurements and has full calibration and configuration capability. See PSS 2A-1Z3 F for applications using the Model PCMV configurator with the Model IMV25 Transmitter. OPTIONAL LCD DIGITAL INDICATOR A digital indicator with on-board pushbuttons is available to display the measurement with a choice of units. The pushbuttons allow zero and span adjustments, as well as routine local configuration changes. Complies with NAMUR 105 overrange and underrange annunciations. Complies with all applicable European Union Directives (“CE” Logo marked on product). UNIQUE PROCESS COVER AND CELL BODY DESIGN Biplanar Construction (Figure 3) maintains the traditional horizontal process connections and vertical mounting by providing a cell body contained between two process covers, while still achieving light weight, small size, and high static pressure rating. Process Covers (Figure 3) are fully supported by the cell body over their entire height. Process Cover Bolts (Figure 3) are enclosed to minimize corrosion and to minimize early elongation with rapid temperature increases. Light Weight provides ease of handling, installation, and direct mounting without requiring costly pipe stands. TRANSMITTER STRUCTURES Traditional and low profile structures (LP1 and LP2) are offered to accommodate and to provide flexibility in transmitter installations. See paragraphs below. Traditional Structure The traditional structure (Figure 4) utilizes the right angle design common to most DP transmitters in use throughout the world. Sensor cavity venting and draining is provided for both vertical and horizontal transmitter installation, using innovative tangential connections to the sensor cavity (Figures 5 and 6).

Optional side vents are offered for sensor cavity venting in the upright position (Figure 7). An extensive variety of process-wetted materials are available for the process covers on this highly versatile and widely used transmitter. Low Profile Structures The low profile structures utilize an in-line design, placing the process connections in line with the transmitter centerline (Figure 8). This allows mounting of the transmitter in the upright position with the process connections facing downward, for connection to vertical process piping or for mounting directly to a three- or five-valve manifold (Figure 9). The low profile structures provide a mounting style similar to that used by competitive CoplanarTM transmitters. This makes it easy to select Foxboro transmitters for both retrofit and new applications where this type of installation is desired. Transmitters with the low profile structure can be attached directly to existing, installed Coplanar manifolds, such as the Rosemount Model 305RC or Anderson Greenwood Models MB3, MB5G, and MB5P, by use of an optional adapter plate (see Figure 10). All parts making up the low profile versions are identical to the parts in the traditional version except for the process covers and the external shape of the sensor cell body. For user convenience, two types of low profile structures are offered, type LP1 and LP2. The process covers are the only transmitter parts that differ between structure types LP1 and LP2. Refer to the sections that follow for further descriptions of low profile structures LP1 and LP2. These transmitters are not typically bracket- mounted. In conjunction with the standard tangential venting and draining design, they are suitable for mounting either vertically (Figure 11) or horizontally, and are suitable for nearly all applications, including liquids, gases, and steam.

For horizontal installation, they can simply be “turned over” (rotated 180 degrees - Figures 12 and 13) to orient the high and low pressure sides in the preferred locations. There is no need to unbolt process covers. The topworks housing can also be rotated, as shown, to orient the conduit connections in the desired position. In the vertical, upright position, they are also self-draining and are ideal for gas flow rate service, when directly mounted to a manifold located above the horizontal pipeline. The vent screw can be omitted for this or other applications, if desired. Low Profile Structure LP2 - Bracket or Direct Mount Structure LP2 is a universal design for either bracket or direct mounting. Drilled and tapped mounting holes facilitate mounting to either new or existing Foxboro brackets (Options -M1, -M2, and -M3), as well as standard brackets supplied with existing Coplanar transmitters (Figures 14 and 15). These transmitters can also be directly mounted to manifolds or process piping and are available with the same optional adapter used with low profile structure LP1 to fit existing Coplanar manifolds (Figure 16). For extra convenience, they use a full- featured vent and drain design, with separate vent and drain screws positioned in each cover for complete venting or draining directly from the sensor cavity. They are normally recommended for upright, vertical installation. FUNCTIONAL SPECIFICATIONS Output Signal and Configuration 4 to 20 mA with HART Communications. When configured for multidrop applications, the mA signal is; fixed at 4 mA to provide power to the device. Configurable using a HART Communicator, Model PCMV Configurator, or optional LCD indicator with on-board pushbuttons. The Model PCMV Configurator, HART Communicator, or optional LCD indicator with pushbuttons provide zeroing at any user entered value. Suppressed Zero and Elevated Zero Suppressed or elevated zero ranges acceptable as long as Span and Range Limits are not exceeded.

This makes transmitter suitable for Safety Shutdown System Applications that require this feature. Current Outputs for Overrange, Fail, and Offline Conditions Square Root Low Flow Cutoff User configurable to provide: Cutoff to Zero at Flows Or Active Point-to-Point Line between Zero and 20 of Maximum Flow (4 of Maximum Differential Pressure). Configuration and Calibration Data, and Electronics Upgradeability All factory characterization data, and user configuration and calibration data, are stored in the sensor. Changing module types may require reconfiguration and recalibration, but all factory characterization data is retained. Configuration Capability (a) Supply Voltage Digital Output: Bidirectional digital signal superimposed on the 4 to 20 mA current signal. 4 to 20 mA: Minimum supply voltage shown in Figure 17 is 11.5 V dc. This can be reduced to 11 V dc by using a plug-in jumper across the test receptacles in the field wiring compartment terminal block. Invensys offers an optional plug- in shorting bar (SB-11) for this purpose. With Fluorinert Fill Fluid Refer to Figure 18. Available Units for Calibrated Range Optional Custom Configuration (Option -C2) For the transmitter to be custom configured by the factory, the user must fill out a data form. If this option is not selected, a standard default configuration will be provided; for example: HART (Version -T) Communications 4 to 20 mA Analog Mode: Analog output signal is updated 30 times per second. A minimum loop load of 250 ohms is required. See Table 1 for communication parameters, and Figure 20 for a typical functional block diagram. See Table 1 for communication parameters and Figure 21 for a typical multidrop functional block diagram. Optional LCD Indicator with On-Board Pushbuttons (Figure 19) Indicator provides: Two lines; five numeric characters on top line (four when a minus sign is needed) and seven alphanumeric characters on bottom line.

Measurement readout; value on top line and units label on bottom line. Configuration and calibration prompts. Calibration Frequency The calibration frequency is five years. See Figure 17. Static Pressure Effect on Differential Pressure The zero and span shift for a 0.7 MPa, 100 psi, change in static pressure is: Position Effect Transmitter may be mounted in any position. Output shift is Electromagnetic Compatibility Refer to Functional Specifications section. Process Cover and Process Connection Gaskets Glass filled ptfe (Chemloy) Process Cover Bolts and Nuts ASTM A193, Grade B7 high strength alloy steel for bolts, and ASTM A194 Grade 2H high strength alloy steel for nuts are standard. Refer to Figure 22. Mounting Position The transmitter may be mounted in any orientation. The measurement of the Foxboro 144LD is based on the Archimedes buoyancy principle. The Foxboro 144LD can easily be supervised and configured remotely with a. Masoneilan Level Transmitters - mmcontrol.com The Foxboro 43AP pneumatic controller is a versatile process instrument controller that can be used to control pressure, temperature, flow and level. As with all process controllers, the Foxboro 43AP pneumatic controller continuously detects the difference between a process measurement and its set point, and produces an output air signal that Foxboro Pressure Transmitter, DCS module: FBMS, FCM We S A Electronic, Pune, from 1999 are famous amongst the esteemed wholesaler trader of an exceptional quality assortment of Engineering Equipment. Offered products range consists of Wika Level Transmitter, Wika Temperature Transmitters, and Wika Pressure Transmitter. PLT Brochures and Manuals - PLT Mag Gage Wisner Controls features pressure transmitters from ABB, Foxboro, and IFM Efector. We stock both gage pressure and differential pressure transmitters along with sanitary gage pressure models. Listed below are our most popular models.

Complete data sheets and instruction manuals EJX210A Yokogawa Electric Corporation Pressure transmitters are used to measure the pressure or level of industrial liquids and gases. The output is transmitted to a control system. Accurate and stable process measurements ensure the safe, reliable, and profitable operation of your plant. Yokogawa Electric Corporation. Klay Instruments Level Switches. SOR level switches have earned a long-time reputation for their high quality, rugged construction and reliable performance under the most demanding applications. All float level switches are individually built with strict attention to detail to meet the exact specifications of your process. The transmitter converts the low-level, high-impedance signal. Sensing mechanism The silicon diaphragm is displaced when pressure is applied from P1 and P2, and the capacitance between the capacitor electrode and the silicon diaphragm changes. Boat Lft Remote Controls, TEC I, TEC II, TEC 1-2, and TEC IV The Foxboro 244LD is an intelligent Transmitter that is designed to measure liquid level, interface or density of liquids. The measurement is based on the principle of Archimedes buoyancy. The Foxboro 244LD can easily be supervised and configured remotely with a PC of HART Hand Terminal. The Foxboro 244LD can also be operated with the local keys. Alfa Laval Potentiometric Level Transmitter Buy Foxboro Liquid Level Transmitter Model 13FA-MS31A5 - P7536. Peak Machinery offers new and used Foxboro Liquid Level Transmitter Model 13FA-MS31A5. Paper equipment and pumps models from top leading brands available. Foxboro 843dp Instruction Manual - atharvaconsultancy.com Rosemount 3051 Transmitter pdf manual download. Also for: Rosemount 3051cf series. Wireless series pressure, level, and flow solutions with wirelesshart protocol (160 pages) Transmitter Emerson Rosemount 3051 Manual.

Transmitter with foundation fieldbus protocol (126 pages) Transmitter Emerson Rosemount 3051CF Series Quick Start Manual Foxboro E83 Flow Meter Calibration Manual Control Room Instruments. We are the supplier and distributor of a wide array of Control Room Instrumentation. The offered products are used in a wide variety of industrial applications to monitor, control and record process parameters such as temperature pressure level flow humidity, moisture, speed-torque, etc. The IGP05S measures a relative pressure with an accuracy of 0.075 of the selected measuring range, ranging from 50 kPa to 345 bar. This makes the IGP05S pressure transmitter less accurate than its bigger brothers, but also a lot cheaper. For less demanding OPERATING GUIDE - SportDOG Conductivity Level Probe is used to determine the presence of a conductive liquid at a set level by sensing conductivity. The probes allow for the measurement of conductivity. A few applications include closed vessels and tank level control. August 3, 2011 - Invensys Operations Management releases the Foxboro 876EC.Foxboro Temp Indicating Controller Manual Viatran Model IDP10 differential pressure transmitter uses silicon sensor technology and microprocessor-based electronics to provide exceptional accuracy and reliability. Modular electronics are NEMA 4X housed with corrosion-resistant epoxy coating. Stainless steel is also available for extremely corrosive and offshore applications. I have been searching Foxboro's website for documentation pertaining to a 13A-MS2 DP Transmitter. I require the following documentation MI022-310 and.

Foxboro Differential Pressure Pneumatic Transmitters The IZMAG is a full featured electromagnetic flow meter offering a wide breath of configurations and features to meet application needs Building on the qualities that have made its predecessors the industry standard in accuracy and longevity, the IZMAG incorporates design and performance features that allow the IZMAG to excel in the most demanding sanitary processing environments. This mi crosensor converts the pressure to a change in resistance, and the resistanc e change is converted to a 4 to 20 mA signal pro-portional to the pressure. Therefore, the transmitter should be calibrated 770 to 1650 mmWC to measure liquid levels of 200 mm to 1000 mm above the nozzle. CONTROL VALVE ACTUATOR testing of most Foxboro Intelligent Transmitters using. FoxCom protocol. Rent the Foxboro HHT Field Communicator. Request Rental Quote Above. JM Test Rental options can help you save capital, get the latest technology, and expand your capabilities. Read online Foxboro Level Transmitters Manual - umtinam.com book pdf free download link book now. All books are in clear copy here, and all files are secure so don't worry about it. Water Level Sensors TE Connectivity Foxboro Manuals. Quick Solutions. Foxboro Field Devices - Manuals, Downloads, and Tools Quick Guide LG01 Guided Wave Radar Level Meter Thu, 21 Jun, 2018 at 4:24 PM. Product Category: Process Equipment, Sub Category: Process Controls Refurbished Foxboro spare parts. Rosemount 3051 Pressure Transmitter Product Data Sheet. Rosemount 3051 Pressure Transmitter Reference Manual. Pressure Instrumentation Ways to Improve Productivity and Process White Paper. The ideal for every industrial manager is for every piece of equipment in their process to function properly at all times.

Designed & Built by ZuPP

 

Designed & Built by ZuPP

 

 

CONTACT

 

 

B.O. Sport

Bospoort 14, B- 3680 Maaseik

+32 89 56 32 24

 

info@bosport.be